Filter Results By:

Products

Applications

Manufacturers

Gas Analyzers

determine the quality and quantity of a gas or gas mixture.

See Also: Gas Analysis, Residual Gas Analyzers, Gas Sensors


Showing results: 286 - 300 of 305 items found.

  • Photometric Ozone Calibrator

    Model T703 - Teledyne Advanced Pollution Instrumentation

    The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.

  • Constant Volume Sampler

    CVS-ONE - HORIBA, Ltd.

    The CVS-ONE series is designed for the measurement of diluted emissions from vehicles and engines. The new integrated operating platform, HORIBA ONE PLATFORM is adopted for the CVS-ONE. The hardware has been significantly downsized from previous designs, reducing test cell footprint requirements. It introduces new functions and is more user-friendly, while still maintaining high accuracy. In conjunction with the MEXA-ONE (Motor Exhaust Gas Analyzer), the system can be used to measure extremely low emission levels such as SULEV. The new CVS reliably supports emission testing requirements of today and into the future.

  • Saybolt Color Analyzer

    optek

    optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.

  • Trace-Level Dilution Calibrator

    Model T700U - Teledyne Advanced Pollution Instrumentation

    The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.

  • Ventilator Test System

    4070 - TSI Inc.

    The Certifier® FA Ventilator Test System 4070 is capable of testing multiple parameters of ventilator performance. It is designed to measure air, oxygen, and nitrous oxide flow and pressure in institutional, home care, field service, laboratory, and production applications. The Certifier FA ventilator test system is a battery-operated flow analyzer that can also test a variety of other medical equipment such as anesthesia gas delivery machines and oxygen concentrators.

  • Trace-Level Photometric Ozone Calibrator

    Model T703U - Teledyne Advanced Pollution Instrumentation

    The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.

  • Gas Analysis

    Sensors, Inc.

    Accurate measurement of gases and their concentrations is critical in many applications, and often poses a major challenge. Sensors' experience with different measurement principles, including NDIR, NDUV, and thermal conductivity, along with the ability to provide special combinations of these techniques within our products, enables us to tackle these challenges. In addition, our experience goes into every detail of our gas analyzers, ensuring reliable results, even under harsh conditions. Our skilled team of experts is happy to assist you in finding the optimized solution for your measurement requirements, with either off-the-shelf components or a customized solution.

  • Carbon / Water Analyzer

    CW‑800 - ELTRA GmbH

    Determination of released carbon dioxide and water is a special requirement for quality control in the cement and lime industry. ELTRA’s CW-800 analyzer is designed for the precise, simultaneous determination of carbon dioxide and water in lime, gypsum and cement from trace level up to 100 % (depending on sample weight). Other sample materials include ores, soil and minerals. The CW-800 is equipped with a resistance furnace with quartz tube for sample oxidation and can provide temperatures up to 1000 °C. The temperature of the CW-800 can be set up in steps of 1 °C and the temperature is fixed during measurement. As common carrier gas in the CW-800 nitrogen is used.

  • Infrared Analyzers

    Model GFC-7000T - Teledyne Analytical Instruments

    The GFC Series gas filter correlation analyzers measure low ranges of gases (CO2, CO2 and N2O detecting models available​ by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.​

  • Infrared Analyzer

    Model GFC-7002T - Teledyne Analytical Instruments

    The GFC Series gas filter correlation analyzers measure low ranges of gases (CO, CO2 and N2O detecting models available by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.​

  • Infrared Analyzer

    Model GFC-7001T - Teledyne Analytical Instruments

    The GFC Series gas filter correlation analyzers measure low ranges of gases (CO2, CO2 and N2O detecting models available by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.​

  • Thermogravimetric Analyzer

    TGA-1000/1500 - Thermtest Instruments

    The Thermogravimetric Analyzer TGA-1000/1500 is a thermal analysis instrument that measures weight changes as a function of temperature or time. The system allows for multiple heating, cooling, and isothermal segments to be linked together to achieve a complex profile. Automatic gas switching is also supported during the temperature program. The vertical hangdown design offers stable and smooth weight readings to be recorded during the experiment. The TGA’s small mass furnace responds quickly to changes in the temperature profile and cools down quickly for fast turn around between experiments. Typical analyses for a TGA-1000/1500 include percent weight loss, onset temperature calculations and residual weight.

  • Multi-Stage Injection Measurement System

    Ono Sokki

    Common rail fuel injection system in diesel engines is a fuel injection system which improves output performance and fuel consumption by purifying exhaust gas (soot, NOX) and reducing noise and vibration.The fuel is completely burned by being sprayed in the form of mist which burns easily at high pressure, and furthermore the combustion timing is optimized with electronic control.In this common rail injection system, injection timing by an electric controlling has great effect on the performance of an engine. So measurement of injection amount, injection rate, and injection timing are very important. FJ-8000 series Multi-Stage Injection Analyzer is able to measure those parameters for every 1 cycle by simulating in the environment which is near to an actual vehicle running.

  • Photolytic True NO2/NO/NOx Analyzer

    Model T200P - Teledyne Advanced Pollution Instrumentation

    The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.

  • ​Paramagnetic Oxygen Analyzer

    Model T802 - Teledyne Monitor Labs

    The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T802 comes with the NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

Get Help